2014년 4월 17일 목요일

2014년 4월 8일 화요일

아황산 가스분석기 MEZUS 110

아황산 가스분석기 MEZUS 110

​​  판매처 : 켐익코퍼레이션    대표전화: 031-737-2121    www.kemikair.com / www.kemik.co.kr



※ 특징

- Ranges : 0~0.1, 0~0.5, 0~1ppm, user selectable
- 7inch TFTLCD touch screen interface
- Ethernet, RS-232, RS-485 & USB ports
- USB interface utilizes for system program update
- Temperature & pressure compensation
- Internal zero(optional)
- Stored data can be retrieved RS-232, USB Interface and TCP/IP network
- In built Data Logger Utilizes NAND-Flash to store up to 5min/1year averaged data


※ 용도 

- 자외선형광법을 이용 극미량의 대기중 SO2를 정확히 측정


※ 사양

- Measuring Items : Sulfur Dioxide(SO2)in ambient air
- Measuring method : Ultraviolet fluorescent method(UVF)
- Range : 0~0.1, 0~0.5, 0~1ppm (selectable)
- Lower Detectable Limit : Less than 0.5ppb
- Repeatability : within ±1% of span gas concentration
- Zero Drift : Less than 1ppb
- Span Drift : within ±1% / full scale(1day)
- Response Time(95%) : Less than 120 seconds(T95)
- Linearity : within ±1% / full scale
- Precision : within 1% of reading or 1ppb
- Ambient temp : 5~40℃
- Analog Output : 0.5V, 0~1V
- Sample flow rate : Stabilized flow control by 700cc/min Critical Orifice
- Particulate filter : 47mm Teflon Filter
- Display : 7inch Graphic LCD
- Comport : Ethernet, USB1.1, RS-232C, RS-485 
- Internal data memory : Measuring data(5min/1yer), Operation history, Messages, Alert
- Power requirement : 220VAC/60Hz or 230VAC/50Hz

질소산화물 가스분석기 MEZUS 210


질소산화물 가스분석기 MEZUS 210 

   ​판매처 : 켐익코퍼레이션    대표전화: 031-737-2121    www.kemikair.com / www.kemik.co.kr 





※ 특징

- Ranges : 0~0.1, 0~0.5, 0~1ppm, user selectable
- 7inch TFTLCD touch screen interface
- Ethernet, RS-232, RS-485 & USB ports
- USB interface utilizes for system program update
- Temperature & pressure compensation
- Internal zero(optional)
- Stored data can be retrieved RS-232, USB Interface and TCP/IP network
- In built Data Logger Utilizes NAND-Flash to store up to 5min/1year averaged data

※ 용도 
- 화학발광법을 이용 극미량의 대기중 NOx(NO,NO2)를 동시에 측정

※ 사양
- Measuring Items : Nitrogen oxide (NO,NO2,NOx)in ambient air
- Measuring method : Chemiluminescence method (CLD)
- Range : 0~0.1, 0~0.5, 0~1ppm (selectable)
- Lower Detectable Limit : Less than 0.5ppb
- Repeatability : within ±1% of span gas concentration
- Zero Drift : Less than 1ppb
- Span Drift : within ±1% / full scale(1day)
- Response Time : Less than 60 seconds(T95)
- Linearity : within ±1% / full scale
- Precision : within 0.2% of reading or 0.5ppb
- Ambient temp : 5~40℃
- Analog Output : 0.5V, 0~1V
- Sample flow rate : Stabilized flow control by 700cc/min Critical Orifice
- Particulate filter : 47mm Teflon Filter
- Display : 7inch TFT-LCD & Touch screen
- Comport : Ethernet, USB1.1, RS-232C, RS-485
- Internal data memory : Measuring data(5min/1yer), Operation history, Messages, Alert
- Power requirement : 220VAC/60Hz or 230VAC/50Hz

일산화탄소 가스분석기 MEZUS 310


일산화탄소 가스분석기 MEZUS 310 

   판매처 : 켐익코퍼레이션 www.kemikair.com / www.kemik.co.kr   대표전화 : 031-737-2121​





※ 특징

- Ranges : 0~50, 0~100ppm, user selectable
- 7inch TFTLCD touch screen interface
- Ethernet, RS-232, RS-485 & USB ports
- USB interface utilizes for system program update
- Temperature & pressure compensation
- Internal zero(optional)
- Stored data can be retrieved RS-232, USB Interface and TCP/IP network
- In built Data Logger Utilizes NAND-Flash to store up to 5min/1year averaged data


※ 용도 

- 비분산 적외선분석법(NDIR GFC)을 적용하여 긴 광로 및 내구성 있는 광학 곡률 미러(Mirror)를 
통하여 극미량의 대기중 일산화탄소를 정확히 측정 


※ 사양

- Measuring Items : Carbon monoxide(CO) in environmental air
- Measuring method : Non dispersed infrared analysis(GFC NDIR)
- Range : 0~50, 0~100ppm (selectable)
- Lower Detectable Limit : Less than 0.05ppm
- Repeatability : within ±0.5% of span gas concentration
- Zero Drift : Less than 0.1ppm
- Span Drift : within ±1% / full scale(1day)
- Response Time : Less than 60 seconds(T95)
- Linearity : within ±1% / full scale
- Precision : 1% of reading or 0.1ppm
- Ambient temp : 5~40℃
- Analog Output : 0~5V, 0~1V
- Sample flow rate : Stabilized flow control by 800cc/min Critical Orifice
- Particulate filter : 47mm Teflon Filter
- Display : 7inch Graphic LCD
- Comport : Ethernet, USB1.1, RS-232C
- Internal data memory : Measuring data(5min/1yer), Operation history, Messages, Alert
- Power requirement : 220VAC/60Hz or 230VAC/50Hz  

오존(O3) 가스분석기 MEZUS 410​


오존(O3) 가스분석기 MEZUS 410

    판매처 : 켐익코퍼레이션 www.kemikair.com / www.kemik.co.kr   대표전화 : 031-737-2121​





※ 특징

- Ranges : 0~0.1, 0~0.5, 0~1ppm, user selectable
- 7inch TFTLCD touch screen interface
- Ethernet, RS-232, RS-485 & USB ports
- USB interface utilizes for system program update
- Temperature & pressure compensation
- Internal zero(optional)
- Stored data can be retrieved RS-232, USB Interface and TCP/IP network
- In built Data Logger Utilizes NAND-Flash to store up to 5min/1year averaged data


※ 용도 

- 자외선흡수법을 이용 극미량의 대기중 오존을 정확히 측정


※ 사양

- Measuring Items : Ozone(O3)in ambient air
- Measuring method : UV Photometry(UV absorption method)
- Range : 0~0.1, 0~0.5, 0~1ppm (selectable)
- Lower Detectable Limit : Less than 0.5ppb
- Repeatability : within ±1% of span gas concentration
- Zero Drift : Less than 1ppb
- Span Drift : within ±1% / full scale(1day)
- Response Time : Less than 50 seconds(T95)
- Linearity : within ±1% / full scale
- Precision : 0.5% of reading or 1ppb
- Ambient temp : 5~40℃
- Analog Output : 0.5V, 0~1V
- Sample flow rate : Stabilized flow control by 800cc/min Critical Orifice
- Particulate filter : 47mm Teflon Filter
- Display : 7inch Graphic LCD
- Comport : Ethernet, USB1.1, RS-232C 
- Internal data memory : Measuring data(5min/1yer), Operation history, Messages, Alert

- Power requirement : 220VAC/60Hz or 230VAC/50Hz

초미세먼지 자동측정기기 MEZUS 610


초미세먼지 자동측정기기 MEZUS 610


    판매처 : 켐익코퍼레이션 www.kemikair.com / www.kemik.co.kr   대표전화 : 031-737-2121​





※ 특징

- Ranges : 0~2,000/5,000ug/m3 user selectable
- 7inch TFTLCD touch screen interface
- Ethernet, RS-232, RS-485 & USB ports
- USB interface utilizes for system program update
- Temperature & pressure compensation
- Stored data can be retrieved RS-232, USB Interface and TCP/IP network
- In built Data Logger Utilizes NAND-Flash to store up to 5min/1year averaged data


※ 용도 

- 베타선흡수법을 이용하여 대기중의 미세먼지(PM10, PM2.5등)를 정확히 측정


※ 사양

- Measuring Items : SPM in the ambient air
- Measuring method : Beta ray attenuation method
- Range : 0~2,000/5,000ug/m3(selectable)
- Repeatability : within ±1% of span gas concentration
- Zero Drift : 0.2%
- Span Drift : within ±0.6% / full scale(1day)
- Linearity : within ±0.3% / full scale
- Ambient temp : 5~45℃
- Analog Output : 0.5V, 0~1V or 4~20mA
- Sample flow rate : 16.7L/min Critical Orifice
- Sample filter : Glass Fiber Roll, L=20m
- Display : 7inch Graphic LCD
- Comport : Ethernet, USB1.1, RS-232C, RS-422 
- Internal data memory : Measuring data(5min/1yer), Operation history, Messages, Alert
- Power requirement : 220VAC/60Hz or 230VAC/50Hz

PM2.5 & PM10 동시 측정기 MEZUS 620

 

 PM2.5 & PM10 동시 측정기 MEZUS 620
       

    판매처 : 켐익코퍼레이션 www.kemikair.com / www.kemik.co.kr   대표전화 : 031-737-2121​



     ※ 특징

  > Beta ray attenuation Dual Dust (PM2.5 & PM10) Analyzer
  > PM10 & PM2.5 Dual Particulate Measurements in Real Time
  > Single filter sopot in position for 12 hours (default): user selectable 1 to 12hours
  > 7-inch TFT LCD touch screen interface
  > Ethernet, RS-232, RS-485 and USB ports
  > USB interface utilizes for System Program Update 
  > Stored data can be retrieved RS-232, USB interface and TCP/IP network
  > Built-in Data Logger utilizes NAND-Flash to store up to 5min/1year average data



      ※ 사양 

  > Range    : 0-1,000ug/m3 to 0-10,000ug/m3 
  > Source    : Carbonium-14(C14) < 100uCi 
  > Lower Detecable Limit : <4ug/m3 (1hour average) 
  > Measurement type   : Continuous Dual Particulate Monitor (PM10 & PM2.5) 
  > Measurement cycle  : 5minutes to 1hour 
  > Sample Flow Rate   : 16.67 liters/min (Dual Flow Control) 
  > Outputs    : 0-5V, RS232/RS485, TCP/IP, USB interface, 8 Status Alarm (5DCV Output) 
  > Inputs    : 4 Digital Input 
  > Display    : 7-inch TFT-LCD & Touch Screen 
  > MCU    : S3C6410-667MHz@ARM11 SOC 
  > Power Requirements  : 110AVC, 220AVC +/-10% 
  > Size    : 480mm(W) x 350mm(H) x 368mm(D)